Terms & Conditions

Contents

Go to -> Company Details

Go to -> Licensing of Oasys software – Licensing Documentation PDF

Go to -> Help with ordering

Privacy and Cookies

Data Security

Website Terms and Conditions

Software Licensing Terms


Privacy and Cookies

We may change this privacy notice from time to time by updating this page.

What information do we collect?

When you use this website, we may collect the following information:

  • the areas of the website that you visit
  • information about your computer, such as which browser you are using, your network location, the type of connection you are using (e.g. broadband, ADSL etc) and your IP address

We do this by using cookies, which are small files that help us track how our visitors use the website and enable us to understand where we can improve your experience. If you would like to find out which cookies we use and the information they track see our Cookies Policy.

Once you submit or register information through our website we will know who you are and your activities on this website and information about you and/or your company may be recorded on our systems. For example, we may ask for personal information when you download our software including:

  • your name
  • company name
  • email address
  • postal address
  • telephone number
  • country where you are based
  • Social media ID
  • your comments/questions
  • services/markets you are interested in

We may also collect personal information from telephone calls and/or other correspondence with you.

What do we do with the information we collect?

The information we capture is used for various purposes. The main purpose is to provide you with our services (whether available via the website or offline). We also use the information for:

  • website development
  • understanding how our visitors interact on the website
  • understanding what our clients are interested in
  • understanding what potential clients are interested in
  • dealing with enquiries/concerns
  • marketing our services and people to you
  • market research
  • service development
  • internal record keeping

Marketing

We would like to provide you with information about our services and other information which we think you may find interesting. We may send you such information by post, email and/or telephone, unless you have asked us not to do so.

We will not provide your personal information to other organisations for marketing purposes without your explicit consent.

If at any time you do not want your information used for direct marketing purposes, please contact us or follow the unsubscribe link in our marketing email messages.

Who do we share this information with?

We may share your personal information with companies acting on our behalf who will only use the information to provide that service. However, we will retain control of your data and any third party service provider that we use must act in accordance with our instructions. We may also share your personal information with a purchaser or potential purchaser of our business.

In some circumstances, we may have to disclose your personal information by law, because a court or the police or other law enforcement agency has asked us for it.

How to get copies of or amend the information we have collected

You may request details of the personal information that we hold about you under data protection laws. If you would like a copy of the information held about you please write to us at oasys@arup.com or at: Data Protection Officer, 13 Fitzroy Street, London, UK, W1T 4BQ. Please note that we may charge a small £10 administration fee for information requests.

If you think any information we have about you is incorrect or incomplete, please email us as soon as possible. We will correct or update any information as soon as we can.

top ]


Data Security

We are committed to ensuring that your information is secure. In order to prevent unauthorised access or disclosure we have put in place suitable physical, electronic and managerial procedures to safeguard and secure the information we collect, including locked cabinets, electronic password protection and pass card access to buildings.

If at any point you suspect or receive a suspicious communication from someone suggesting they work for Oasys or a website claiming to be affiliated with Oasys, please forward the communication to us or report the incident by email to oasys@arup.com or in writing to Oasys, 13 Fitzroy Street, London, UK, W1T 4BQ as soon as possible.

top ]


Website Terms and Conditions

The contents of this web site are protected by copyright and other intellectual property rights under international conventions. No copying of any words, images, graphic representations or other information contained in this web site is permitted without the prior written permission of the webmaster for this site.

Oasys accepts no responsibility for the content of any external site that links to or from this site.

top ]


Software Licensing Terms

Terms and Conditions of Purchase

The full conditions of purchase and maintenance for all Oasys software are set out in the Oasys Software Licence and Support Agreement. All prices are subject to TAX at the current rate.

Prices and specifications are subject to change without notice – please ask for a written quotation.

Although every care has been taken to ensure the accuracy of all information contained herein, the contents do not form or constitute a representation, warranty, or part of any contract.

Superseded Versions of Terms and Conditions

Oasys keeps copies of all superseded versions of its terms and conditions.

Maintenance & Support Services

Twelve months support and maintenance is included with most products. Thereafter maintenance is typically 20% of the current sales price.

An annual maintenance service is available for most programs after the first year.

This service includes:

  • telephone/fax/email/web based support
  • free software updates available via internet download
  • personalised output header for many products

Safe Change Log

All notable changes to Safe will be documented within the change log.

New Features

  • New mesh generator incorporated
  • Automatic strength reduction method for slope stability added
  • Additional theories for storm loading added

Fixes

  • NCR 8161: Graph does not change for revised x-y coordinates when using element group.
    Fixed 13/6/2014: released in Safe 19.1.0.12 (30/6/2014)
  • NCR 9360: Company name and logo do not show on printed output.
    Fixed 1/9/2014: released in Safe 19.1.0.15 (2/9/2014)
  • NCR 9374: program crashed creating permeabilities in seepage analysis.
    Fixed 1/9/2014: released in Safe 19.1.0.15 (2/9/2014)
  • NCR 9375: Graph plotting unacceptably slow for large problems.
    Fixed 1/9/2014: released in Safe 19.1.0.15 (2/9/2014)
  • NCR 9380: Brick parameters corrupted in reading files or new materials.
    Fixed 1/9/2014: released in Safe 19.1.0.15 (2/9/2014)
  • NCR 9422: Program crashed plotting bending moment graph.
    Fixed 16/9/2014: released in Safe 19.1.0.16 (18/9/2014)
  • NCR 9423: Get “encountered an improper argument” adding a run.
    Fixed 16/9/2014: released in Safe 19.1.0.16 (18/9/2014)
  • NCR 9205: Program crashed if number of seepage restraints greater than displacement restraints.
    Fixed 19/9/2014: released in Safe 19.1.0.17 (23/9/2014)
  • NCR 9430: Plotting of FoS graphs failed (consequence of fix to NCR 9422)
    Fixed 19/9/2014: released in Safe 19.1.0.17 (23/9/2014)
  • NCR 9437: Occasionally files crashed on analysis.
    Fixed 23/9/2014: released in Safe 19.1.0.18 (24/9/2014)
  • SAFE-2: Element tabulated results not working.
    Fixed 13/1/2015: released in Safe 19.1.1.22 (21/1/2015)
  • SAFE-3: Deleting springs causes a crash.
    Fixed 16/1/2015: released in Safe 19.1.1.22 (21/1/2015)
  • SAFE-4: Plotting incremental displacement after cumulative causes a crash.
    Fixed 13/1/2015: released in Safe 19.1.1.22 (21/1/2015)
  • SAFE-7: Re-running a previous v19.0 analysis failed due to insufficient space for restraining nodes.
    Fixed December 2014: released in Safe 19.1.1.22 (21/1/2015)
  • SAFE-7: Re-running a previous v19.0 analysis failed due to insufficient space for restraining nodes.
    Fixed December 2014: released in Safe 19.1.1.23 (6/2/2015) (Build 22 had wrong version of DLL.)
  • SAFE-9: Plotting bending moment from effective stress no longer working.
    Fixed 29/1/2015: release in Safe 19.1.1.23 (6/2/2015)
  • SAFE-10: Problem including curved lines does not mesh.
    Fixed 9/9/2015: released in Safe 19.1.1.24 (18/9/2015)
  • SAFE-11: Line joining 2 ends of a curve is not added.
    Fixed 9/9/2015: released in Safe 19.1.1.24 (18/9/2015)
  • SAFE-13: Mesh with sloping line added after gridlines causes crash.
    Fixed 26/4/2016: released in Safe 19.1.1.25 (27/4/2016)
  • SAFE-16 – Mesh renumbering retains old restraints.
    Released in SP1 build 30.
  • SAFE-17 – Storm loading fails to get same result in 19.1 as 19.0.
    Released in SP1 build 30.
  • SAFE-20 – Change contour plotting to vector graphics
    Released in SP1 build 30.
  • SAFE-21 – Bug in editing multiple lines
    Fixed and released in SP1 build 31 (31 May 2017).
  • SAFE-22 – Program crashes inserting a grid line
    Fixed and released in SP1 build 31 (31 May 2017)

New Features

  • Object snap added for drawing mesh
  • Regular mesh generation improved
  • Graphical setting of pressure loads and seepage restraints added
  • Plotting of graphs completely revised: now available outside of graphical output view
  • Deletion of runs now available
  • Analysis progress dialog completely revised with graph showing convergence progress
  • Material drag and drop enabled in graphical input view
  • Crosshair option added to graphical input view
  • Escape key now clears current selection of nodes / elements / other drawn objects
  • Selection of sequence now available.
  • Navigation between runs follows event order, not run number order (SP3 onwards) [#4941]
  • Can plot bending moment etc from total or effective stresses (SP3 onwards) [#4859]
  • Can choose to delete or redisplay an existing graph (SP3 onwards) [#4977]
  • Can choose how many points to plot along a graph line (SP3 onwards) [#4977]
  • Can manually recover results file (SP4 build 29 onwards) [#5469]
  • Can plot stresses and other gauss point results at nodes, against time or increment (SP4 build 30 onwards) [#5731]
  • Can plot other components of stress on line graph (SP5 build 34 onwards, unit factors corrected in build 36) [#6077]
  • List of all nodes with springs created on reading file (SP5 build 37) [#6288]
  • Smoothed contour plotting made available for user-defined element variable (SP5 build 46) [#7859]
  • Bending axis can be shown on graphical output view (SP5 build 49)

Fixes

  • NCR 3977: graphics memory filled during drawing operations – program hangs.
    Fixed 9/9/2009: released in Safe 19.0.1.19 15/9/2009.
  • NCR 3978: graphs of parameters versus time or increment not working if grapical output open.
    Fixed 15/9/2009: released in Safe 19.0.1.19 15/9/2009.
  • NCR 3899: cumulative load plotting not correct for sequence ALL.
    Fixed 15/9/2009: released in Safe 19.0.1.19 15/9/2009.
  • NCR 4049: Element list graphs don’t plot if graphical output view is open.
    Fixed 28/9/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4050: Error converting Ta parameter in void material table.
    Fixed 28/9/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4098: Pore pressure contours initially plot with very small interval.
    Fixed 7/10/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4109: Deleted runs reappear when data file re-opened.
    Fixed 22/10/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4110: Cursor disappears in materials area of Gateway.
    Fixed 21/10/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4128: Line split not always working properly.
    Fixed 28/10/09: new toolbar button which extends 2 selected lines until they intersect. Released in Safe 19.0.2.20 16/11/2009.
  • NCR 4129: Undo corrupts mesh data for dxf import.
    Fixed 22/10/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4135: Tables with symbols in headers do not print correctly.
    Workaround 29/10/09: reinstated tabular output (NCR 4227). Released in Safe 19.0.2.20 16/11/2009.
  • NCR 4137: Isotropic settings should be revised – move to individual material type tables and amend title.
    Fixed 23-26/10/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4138: Graphical export buttons are displaced.
    Fixed 23/10/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4147: Missing help message for strength increase in Mohr-Coulomb material table.
    Fixed 26/10/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4167: “Invalid argument encountered” message when navigating between runs.
    Fixed 3/11/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4217: Incorrect grid nodes from previous version show as diamond symbols in graphical input.
    Fixed 13/11/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4218: Gridline data incorrectly shown as very large coordinates (100000m).
    Fixed 13/11/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4225: Graphs of displacement plot very slowly.
    Fixed 16/11/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4226: Graph plotting of strain is not enabled.
    Interim fix sent to user 30/9/09: Completed fix 16/11/09: released in Safe 19.0.2.20 16/11/2009.
  • NCR 4288: Springs not made active when entered in graphical input view.
    Fixed 16/4/2010: released in Safe 19.0.3 [16/7/2010]
  • NCR 4560: Mesh generation can fail crytically.
    Fixed 16/4/2010 in GSA code: released in Safe 19.0.3 [16/7/2010]
  • NCR 4561: If wells are switched off and on, the convergence material properties can’t be correctly reset.
    Fixed 19/4/2010: released in Safe 19.0.3 [16/7/2010]
  • NCR 4608: Averaged values for seepage velocity and hydraulic gradient not desirable.
    Fixed 16/4/2010 : released in Safe 19.0.3 [16/7/2010]
  • NCR 4860: Graphs around arch default to plot against y coordinate.
    Fixed 6/7/2010: released in Safe 19.0.3 [16/7/2010]
  • NCR 4867: Hydraulic gradient components not correctly shown on dropdown list in graphical output.
    Fixed 14/6/2010: released in Safe 19.0.3 [16/7/2010]
  • NCR 4871: Graph options dialog – Line segment dropdown list doesn’t expand correctly.
    Fixed 6/7/2010: released in Safe 19.0.3 [16/7/2010]
  • NCR 4940: Allow easier pasting into material tables.
    Fixed 6/7/2010: released in Safe 19.0.3 [16/7/2010]
  • NCR 4942: Remove message asking if file should be saved on completion of analysis.
    Fixed 6/7/2010: released in Safe 19.0.3 [16/7/2010]
  • NCR 4949: Fix problem in graphical views for imperial units (kip/ft system).
    Fixed 8/7/2010: released in Safe 19.0.3 [16/7/2010]
  • NCR 5131: Crash in Windows 7 when saving any new file or existing file with different name.
    Fixed 21/9/2010: released in Safe 19.0.4 [5/11/2010]
  • NCR 5170: Cannot plot BM, SF etc along an inclined element set.
    Fixed 30/9/2010: released in Safe 19.0.4 [5/11/2010]
  • NCR 5171: Some sequences not shown in dropdown list.
    Fixed 30/9/2010: released in Safe 19.0.4 [5/11/2010]
  • NCR 5240: Invalid graph axis causes crash.
    Fixed 14/10/2010: released in Safe 19.0.4 [5/11/2010]
  • NCR 5245: Adding a run when it has previously been deleted does not work.
    Fixed 15/10/2010: released in Safe 19.0.4 [5/11/2010]
  • NCR 5344: Change default mode for graphical input to Zoom rather than select nodes.
    Fixed 5/11/2010: released in Safe 19.0.4 [5/11/2010]
  • NCR 5358: Box for “use element list” was incorrectly ticked on opening graph options dialog .
    Fixed 5/11/2010: released in Safe 19.0.4 [5/11/2010]
  • NCR 5397: Can’t specify correct material for ubiquitous joints.
    Fixed 19/11/2010: released in Safe 19.0.4.28 [23/11/2010]
  • NCR 5405: Bug introduced in 19.0.4.27 – changing max iterations did not work.
    Fixed 19/11/2010: released in Safe 19.0.4.28 [23/11/2010]
  • NCR 5399: Plotting graph along very edge of model does not work.
    Fixed 19/11/2010: released in Safe 19.0.4.28 [23/11/2010]
  • NCR 5469: Add feature to manually recover results files.
    Done 30/11/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5476: On moving run, not all views are correctly updated.
    Fixed 2/12/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5492: Name of backup file not correct.
    Fixed 3/12/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 4288: Fixed problem where springs set active in every run when added on graphical input view.
    Fixed 10/12/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5548: Materials incorrectly shown as anisotropic when opening previously saved file.
    Fixed 9/12/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5551: Program crashes if adding runs after deleting runs and going straight to graphics.
    Fixed 6/12/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5552: Tangential loads not plotted correctly.
    Fixed 10/12/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5558: Cannot view graphical output after analysing all runs.
    Fixed 14/12/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5559: Switching to cumulative load display does not always work.
    Fixed 14/12/2010: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5560: Direct editing of stage titles in stage tree view does not work.
    Fixed 14/12/2010 by disabling the direct retype option: released in Safe 19.0.4.29 [15/12/2010]
  • NCR 5566: Moving between runs can corrupt data if unsaved data in a table in original run.
    Fixed 15/12/2010: release in Safe 19.0.4.29 [15/12/2010]
  • NCR 5731: Plotting variables against time/increment not always available in Windows 7.
    Fixed 18/2/2011: released in Safe 19.0.4.30 [18/2/2011]
  • NCR 5796: Plotting of cumulative loads was incorrect when Run 1 is Event 0.
    Fixed 7/3/2011: released in Safe 19.0.4.31 [15/3/2011]
  • NCR 5812: Incremental mesh generation can lead to overlaid areas of mesh.
    Fixed 11/3/2011: released in Safe 19.0.4.31 [15/3/2011]
  • NCR 5856: Array storage revised to allow analysis of larger problems.
    Fixed 25/3/2011: released in Safe 19.0.5.34 [8/4/2011]
  • NCR 5857: Gauss to node extrapolation produced wobbly contours.
    Fixed 29/3/2011: released in Safe 19.0.5.34 [8/4/2011]
  • NCR 5862: Deleting pressure loads does not update graphical input view.
    Fixed 30/3/2011: released in Safe 19.0.5.34 [8/4/2011]
  • NCR 5878: Thrust plots incorrect for a wide pile (axisymmetric).
    Fixed 4/4/2011: released in Safe 19.0.5.34 [8/4/2011]
  • NCR 6076: Plotting groups of elements did not work correctly in graphical input.
    Fixed 25/5/2011: released in Safe 19.0.5.35 [29/7/2011]
  • NCR 6232: Spring force tabular output incorrect (title was incremental, value was cumulative).
    Fixed 28/7/2011: released in Safe 19.0.5.35 [29/7/2011]
  • NCR 6234: Batch analysis for all runs hangs at end if deleted runs are present.
    Fixed 28/7/2011: released in Safe 19.0.5.35 [29/7/2011]
  • NCR 6278: Sequence page blank when only 1 sequence (i.e. All runs).
    Fixed 30/3/2011: released in Safe 19.0.5.34 [8/4/2011]
  • NCR 6281: Repeated click of Next Run button causes crash.
    Fixed 23/8/2011: released in Safe 19.0.5.36 [26/8/2011]
  • NCR 6282: Bending moment graphs not working when axis defined by coordinates.
    Bug introduced in Build 35 in error. Fixed 23/8/2011: released in Safe 19.0.5.36 [26/8/2011]
  • NCR 6435: Data corrupted after a program crash.
    Fixed 17/10/2011: released in Safe 19.0.5.38 [10 Feb 2012]
  • NCR 6773: Cannot mesh areas which include curved lines.
    Fixed 10/2/2012: released in Safe 19.0.5.38 [10 Feb 2012]
  • TWK 6902: Amend reading of a pore pressure data file to assist storm loading analysis.
    Fixed 9/3/2012: released in Safe 19.0.5.39 [13/3/2012]
  • NCR 6903: Analysis crashed for problems with Modified Cam Clay material.
    Fixed 9/3/2012: released in Safe 19.0.5.39 [13/3/2012]
  • NCR 6957: Data and results not correctly read back if file contained deleted runs.
    Fixed 26/3/2012: released in Safe 19.0.5.40 [27/3/2012]
  • NCR 7349: Seepage velocities incorrectly displayed in m/day not m/s.
    Fixed 21/8/2012: released in Safe 19.0.5.42 [23/10/2012]
  • NCR 7529: Averaged stress plots incorrect if pore pressure plotted and then changed run.
    Fixed 23/10/2012: released in Safe 19.0.5.42 [23/10/2012]
  • NCR 7623: Shear and thrust plots did not distinguish between total and effective stress derivation.
    Fixed 19/11/2012: released in Safe 19.0.5.44 [30/11/2012]
  • NCR 7664: Fortran DLL omitted from installer (svml_dispmd.dll).
    Fixed 30/11/2012: released in Safe 19.0.5.44 [30/11/2012]
  • NCR 7861: Bending moment plot around tunnel lining did not plot correctly.
    Fixed March 2013: released in Safe 19.0.5.46 [15/05/2013]
  • NCR 8048: Graph of displacement did not plot correctly through unevenly sized elements.
    Fixed May 2013: released in Safe 19.0.5.46 [15/05/2013]
  • NCR 4686: Axisymmetric materials revert to plane strain after bending moment plotting.
    Fixed 28/5/2014: released in Safe 19.0.5.49 [5/6/2014]
  • NCR 6077: Can’t plot principal stresses on graph.
    Fixed 23/08/2011 in dev code: released in Safe 19.0.5.49 [5/6/2014]
  • NCR 9032: Delete Results button on Runs dialog also deletes run data.
    Fixed 27/5/2014: released in Safe 19.0.5.49 [5/6/2014]
  • NCR 9057: Strange results for bending moment plot around tunnel.
    Fixed 4/6/2014: released in Safe 19.0.5.49 [5/6/2014]

New Features

  • Input and output menu items are filtered for problems defined as steady state seepage only.
  • Generate Mesh and Erase Mesh buttons added to the Graphics toolbar for ease of access.
  • New colouring system adopted for material shading in graphical input view. (Build 7 onwards)
  • Filled contour colours revised and units added to legend. (Build 7 onwards)
  • Cumulative loading display added as default. Toggle back to run loading using new button on toolbar. (Build 7 onwards)
  • Mesh generation nodes shown in separate table. (Build 7 onwards)
  • Allow change of material type by area. (Build 7 onwards)
  • Allow mouse wheel zoom in/out. (Build 7 onwards)
  • Dxf import improved – can edit tolerance for coincident nodes and set number of divisions. (Build 7 onwards)
  • Graphical output revised to show Y direction results by default. (Build 7 onwards)
  • Multiple column graph export reinstated (use Graphics .. Export Graph Data command, not graph right-click menu). (Build 7 onwards)
  • Undo command extended to more operations in graphical input view, and all runs. (Build 7 onwards)
  • New area generate button added, to create area around a clicked point. (Build 7 onwards)

Fixes

  • Terminology wrong way round for hysteresis in ubiquitous joints data.
    [NCR 2948](Fixed 12 August 2008; released in Build 1)
  • NCR 2959 : Thrust on axisymmetric problem flips sign part way down pile
    (Fixed 28 July 2008; released in Build 1)
  • Shading of areas containing arcs not correct
    [NCR 3015](Fixed 15 August 2008; released in Build 2)
  • Split Crossing Lines doesn’t split at ends of existing lines.
    [NCR 3016](Fixed 15 August 2008; released in Build 2)
  • Line selection not working properly.
    [NCR 3017](Fixed 15 August 2008; released in Build 2)
  • Program crashed in seepage analysis for one particular data file.
    [NCR 3047](Fixed 21 August 2008; released in Build 2)
  • Program crashed in seepage analysis for files with large numbers of elements
    (Fixed 2 September 2008; released in Build 3)
  • General materials table not updated when adding new run – stayed at Run 1 display
    (Fixed 7 October 2008; released in Build 7)

New Features

  • A new mesh generator allows individual nodes and internal lines to be specified. The revised meshing interface provides Undo functionality, Sculpt options to copy/translate/mirror/split groups of elements, and filtering of items viewed.
  • A ‘Gateway’ window has been implemented to provide easy access to input data, tabular data and graphical views.
  • The Safe Toolbar has been implemented to provide easy access to the most frequently used views and commands.
  • The menu structure has been re-arranged to provide a separate ‘Graphics’ menu to access settings for the Graphical Output view.
  • The Graph view now allows rescaling, editing of axis titles, resetting of line colours and symbols, and easier enveloping of results.
  • Multi-segmented graph lines should now be entered via a node list (for BM / SF/ Thrust plotting only.) (Release 11 onwards.)
  • Seepage restraints can now be toggled on or off via a button on the Graphical toolbar. (Release 13 onwards.)
  • Choice of unit options added for plotting bending moment, shear force or thrust for axiymmetric problems. (Release 14 onwards.)
  • Periodic web activation for Arup and Unipac editions added. (Release 17 onwards.)

Fixes

  • Plotting graphs other than bending moment along multi-segmented lines re-sets the origin for each line segment.
    [NCR 1474](Fixed 18 April 2007; released in Release 1)
  • Results file path was not correctly created, if path had a full stop before the one preceding the data file suffix.
    [NCR 1510](Fixed 18 May 2007; released in Release 1)
  • Release 1 showed GSA analysis option which should have been disabled (feature under development/ used for testing).
    [NCR 1696](Fixed 11 July 2007; released in Release 2)
  • Selection and deselection of nodes and elements was still too slow for large models .
    [NCR 1697](Fixed 17 July 2007; released in Release 3; consequent disappearing cursor in graphical output fixed in Release 4.)
  • Graphs of variable versus increment did not work.
    [NCR 1898](Fixed 17 August 2007; released in Release 5.)
  • Only part of one bending moment graph shown. (Problem was with tolerance deciding whether line cut through element was common to bending axis.)
    [NCR 1899](Fixed 17 August 2007; released in Release 5.)
  • Trying to move nodes produced odd results.
    [NCR 1900](Fixed 18 August 2007; released in Release 5.)
  • Shear force and thrust plots incorrect – showed bending moment results.
    [NCR 1941](Fixed 31 August 2007; released in Release 6.)
  • Graph views – combining curves not correct. Also, export curves not a useful format.
    (Fixed 22 October 2007 and reinstated Graph/Export Data menu option ; released in Release 7.)
  • NCR 1942: Filled contours / legend not correctly updated to stay in sync.
    (Fixed 09 November 2007; released in Release 8.)
  • NCR 1946: Contours of stress sometimes plot in the wrong direction.
    (Fixed 08 November 2007; released in Release 8.)
  • NCR 2236: Displacement graphs – combining curves still not correct.
    (Fixed 08 November 2007; released in Release 8.)
  • NCR 2236: Bending moment graphs – combining curves not correct for vertical axes – points sorted in increasing x instead of y.
    (Fixed 16 November 2007; released in Release 9.)
  • NCR 2316: Shear force / thrust plots – forces resolved along incorrect axes. Affected non-horizontal bending axes.
    (Fixed 7 December 2007; released in Release 11.)
  • NCR 2441: Problem accessing results files when data file has full stop in filename.
    (Fixed 4 January 2008; released in Release 13)
  • NCR 2442: Fails to plot stress etc on line through very thin elements (10mm wide)
    (Fixed 25 January 2008; released in Release 13)
  • NCR 2542: Thrust on axisymmetric problem not plotted correctly.
    (Fixed 31 January 2008; released in Release 14) (Subsequent problem on moving between runs and updating plots fixed 13 Mar 2008, released in Release 16.)
  • NCR 2492: Gridlines not saving to file
    (Fixed 28 February 2008; released in Release 15)
  • NCR 2548 : Autogeneration of areas leads to duplicate nodes / zero length lines if gridlines closely spaced.
    (Fixed 28 February 2008; released in Release 15)